Fatal Error: Can't alloc dataspace in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
Warning: alloc datasize:976632435 in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
6ES7134-4JB00-0AB0 ET200S, EL-MOD., 2AI TC, +/-80MV, 15BIT
SIMATIC DP, ELECTRONIC MODULE FOR ET 200S, 2 AI TC 15 MM WIDE, 15 BIT + SIGN +/-80MV; CHARACTERISTICS LINEARIZATION FOR THERMOELEMENTS OF: B, E, J, K, L, N, R, S, T TYPES, CYCLE TIME 65 MS/CHANNEL WITH LED SF (GROUP FAULT)
Supply voltage
Load voltage L+
Rated value (DC)
24 V; From power module
Reverse polarity protection
Yes
Input current
from load voltage L+ (without load), max.
30 mA
from backplane bus 3.3 V DC, max.
10 mA
Power loss
Power loss, typ.
0.6 W
Address area
Address space per module
Address space per module, max.
4 byte
Analog inputs
Number of analog inputs
2
permissible input voltage for voltage input (destruction limit), max.
10 V; Permanent
Cycle time (all channels) max.
Number of active channels per module x basic conversion time
Input ranges
Voltage
Yes
Thermocouple
Yes
Input ranges (rated values), voltages
-80 mV to +80 mV
Yes
Input resistance (-80 mV to +80 mV)
1 MΩ
Input ranges (rated values), thermocouples
Type B
Yes
Input resistance (Type B)
1 MΩ
Type E
Yes
Input resistance (Type E)
1 MΩ
Type J
Yes
Input resistance (type J)
1 MΩ
Type K
Yes
Input resistance (Type K)
1 MΩ
Type L
Yes
Input resistance (Type L)
1 MΩ
Type N
Yes
Input resistance (Type N)
1 MΩ
Type R
Yes
Input resistance (Type R)
1 MΩ
Type S
Yes
Input resistance (Type S)
1 MΩ
Type T
Yes
Input resistance (Type T)
1 MΩ
Thermocouple (TC)
Temperature compensation
internal temperature compensation
Not possible
external temperature compensation with compensations socket
Yes; possible, one external compensating box per channel
Characteristic linearization
parameterizable
Yes; Type B, E, J, K, L, N, R, S, T to IEC 584
Cable length
Cable length, shielded, max.
50 m
Analog value generation
Measurement principle
integrating
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.
16 bit; 15 bits + sign
Integration time, parameterizable
Yes
Integration time, ms
16,7 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz
60 / 50 Hz
Conversion time (per channel)
65 ms; 55 / 65 ms (additional 20 ms on activated wire-break test)
Smoothing of measured values
parameterizable
Yes; In four stages by means of digital filtering
Step: None
Yes; 1 x cycle time
Step: Low
Yes; 4 x cycle time
Step: Medium
Yes; 32 x cycle time
Step: High
Yes; 64 x cycle time
Encoder
Connection of signal encoders
for voltage measurement
Yes
Errors/accuracies
Linearity error (relative to input range), (+/-)
0.01 %
Temperature error (relative to input range), (+/-)
0.0050 %/K
Crosstalk between the inputs, min.
-50 dB
Repeat accuracy in steady state at 25 °C (relative to input area), (+/-)
0.05 %
Operational error limit in overall temperature range
Voltage, relative to input area, (+/-)
0.6 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area, (+/-)
0.4 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.
70 dB
Common mode interference (USS < 2.5 V) , min.
90 dB
Isochronous mode
Isochronous mode (application synchronized up to terminal)
No
Interrupts/diagnostics/status information
Diagnostic messages
Diagnostic functions
Yes; Can be read out
Wire-break
Yes; A break in the wire is only detected for thermocouples
Group error
Yes
Overflow/underflow
Yes
Diagnostics indication LED
Group error SF (red)
Yes
Parameter
Remark
4 byte
Diagnostics wire break
Disable / enable (wire break is detected only in thermocouples)
Measurement type/range
Deactivated/ +/- 80 mV/ +/- 250 mV/ +/- 500 mV/ +/- 1 V / TC-EL Type T (Cu-CuNi)/ TC-EL Type K (NiCr-Ni)/ TC-EL Type B (PtRh-PtRh)/ TC-EL Type N (NiCrSi-NiSi)/ TC-EL Type E (NiCr-CuNi)/ TC-EL Type R (PtRh-Pt)/ TC-EL Type S (PtRh-Pt)/ TC-EL Typ J
Fatal Error: Can't alloc dataspace in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16
Warning: alloc datasize:976632435 in /www/wwwroot/www.kollewin.com/system/secache/secache.php on line 617
Warning: fopen(/www/wwwroot/www.kollewin.com/system/logs/error.txt): failed to open stream: Permission denied in /www/wwwroot/www.kollewin.com/system/library/log.php on line 12
Warning: fwrite() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 14
Warning: fclose() expects parameter 1 to be resource, boolean given in /www/wwwroot/www.kollewin.com/system/library/log.php on line 16