6ES7416-3XR05-0AB0 CPU 416-3, 11.2 MB, 3 INTERFACES

Product Code: 6ES7416-3XR05-0AB0

Availability: In Stock

Price: $6,212.95
  
 
Artikelnummer 6ES7416-3XR05-0AB0
CiR - Configuration in RUN
CiR synchronization time, basic load 100 ms
CiR synchronization time, time per I/O slave 10 µs
Supply voltage
24 V DC No
Input current
from backplane bus 5 V DC, typ. 1.1 A
from backplane bus 5 V DC, max. 1.3 A
from backplane bus 24 V DC, max. 450 mA
from interface 5 V DC, max. 90 mA
Power losses
Power loss, typ. 5.5 W
Power loss, max. 6 W
Memory
Work memory
● Integrated 11.2 Mbyte
● integrated (for program) 5.6 Mbyte
● integrated (for data) 5.6 Mbyte
● expandable No
Load memory
● expandable FEPROM Yes
● expandable FEPROM, max. 64 Mbyte
● integrated RAM, max. 1 Mbyte
● expandable RAM Yes
● expandable RAM, max. 64 Mbyte
Backup
● present Yes
● with battery Yes
● without battery No
Battery
Backup battery
● Backup current, typ. 125 µA
● Backup current, max. 550 µA
CPU processing times
for bit operations, typ. 30 ns
for word operations, typ. 30 ns
for fixed point arithmetic, typ. 30 ns
for floating point arithmetic, typ. 90 ns
CPU-blocks
DB
● Number, max. 10 000
● Size, max. 64 kbyte
FB
● Number, max. 5 000
● Size, max. 64 kbyte
FC
● Number, max. 5 000
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of free cycle OBs 1
● Number of time alarm OBs 8
● Number of delay alarm OBs 4
● Number of time interrupt OBs 9
● Number of process alarm OBs 8
● Number of DPV1 alarm OBs 3
● Number isochronous mode OBs 4
● Number of multicomputing OBs 1
● Number of background OBs 1
● Number of startup OBs 3
● Number of asynchronous error OBs 9
● Number of synchronous error OBs 2
Nesting depth
● per priority class 24
● additional within an error OB 2
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
Counting range
— lower limit 0
— upper limit 999
IEC counter
● present Yes
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
Data areas and their retentivity
Flag
● Number, max. 16 kbyte
● Retentivity available Yes
● Number of clock memories 8
Data blocks
● Number, max. 10 000
● Size, max. 64 kbyte
Local data
● adjustable, max. 32 kbyte
● preset 16 kbyte
Address area
I/O address area
● Inputs 16 kbyte
● Outputs 16 kbyte
of which, distributed
— MPI/DP interface, inputs 2 kbyte
— MPI/DP interface, outputs 2 kbyte
— DP interface, inputs 8 kbyte
— DP interface, outputs 8 kbyte
Process image
● Inputs, adjustable 16 kbyte
● Outputs, adjustable 16 kbyte
● Inputs, default 512 byte
● Outputs, default 512 byte
● consistent data, max. 244 byte
● Access to consistent data in process image Yes
Subprocess images
● Number of subprocess images, max. 15
Digital channels
● Inputs 131 072
● Outputs 131 072
● Inputs, of which central 131 072
● Outputs, of which central 131 072
Analog channels
● Inputs 8 192
● Outputs 8 192
● Inputs, of which central 8 192
● Outputs, of which central 8 192
Hardware configuration
Expansion devices, max. 21
Multicomputing Yes
Interface modules
● Number of connectable IMs (total), max. 6
● Number of connectable IM 460s, max. 6
● Number of connectable IM 463s, max. 4
Number of DP masters
● Integrated 2
● via IM 467 4
● Via CP 10
● Mixed mode IM + CP permitted No
● via interface module 1
● Number of pluggable S5 modules (via adapter capsule in central device), max. 6
Number of IO Controllers
● Integrated 0
● Via CP 4
Number of operable FMs and CPs (recommended)
● PROFIBUS and Ethernet CPs 14
Slots
● Required slots 2
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Resolution 1 ms
● Deviation per day (buffered), max. 1.7 s
● Deviation per day (unbuffered) max. 8.6 s
Operating hours counter
● Number 16
● retentive Yes
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP No
● to IF 964 DP Yes
Time difference in system when synchronizing via
● MPI, max. 200 ms
Digital outputs
integrated channels (DO) 0
Interfaces
Number of USB interfaces 0
Number of parallel interfaces 0
Number of 20 mA interfaces (TTY) 0
Number of RS 232 interfaces 0
Number of RS 422 interfaces 0
Number of other interfaces 0
1st interface
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
MPI
● Number of connections 44
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
DP master
● Number of connections, max. 32
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 32
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
Address area
— Inputs, max. 2 kbyte
— Outputs, max. 2 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search No
● Address area, max. 32
● User data per address area, max. 32 byte
● User data per address area, of which consistent, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes
— S7 routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) No
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Functionality
● DP master Yes
● DP slave Yes
DP master
● Number of connections, max. 32
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
● Address area, max. 32
● User data per address area, max. 32 byte
● User data per address area, of which consistent, max. 32 byte
Services
— Routing Yes
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
3rd interface
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Automatic detection of transmission speed No
Functionality
● MPI No
● DP master Yes
● DP slave Yes
DP master
● Number of connections, max. 32
● Transmission rate, min. 9.6 kbit/s
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 125
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV0 Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— User data per DP slave, max. 244 byte
— Inputs, max. 244 byte
— Outputs, max. 244 byte
— Slots, max. 244
— per slot, max. 128 byte
DP slave
● Number of connections 32
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search No
● Address area, max. 32
● User data per address area, max. 32 byte
● User data per address area, of which consistent, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes
— S7 routing Yes
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client Yes
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) No
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes
Number of DP masters with isochronous mode 3
User data per isochronous slave, max. 244 byte
equidistance Yes
shortest clock pulse 1 ms
max. cycle 32 ms
Communication functions
PG/OP communication Yes
● Number of connectable OPs without message processing 63
● Number of connectable OPs with message processing 63
Data record routing Yes
Global data communication
● supported Yes
● Number of GD loops, max. 16
● Number of GD packets, transmitter, max. 16
● Number of GD packets, receiver, max. 32
● Size of GD packets, max. 54 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
S7 communication
● supported Yes
● as server Yes
● As client Yes
● User data per job, max. 64 kbyte
● User data per job (of which consistent), max. 462 byte
S5-compatible communication
● supported Yes
● User data per job, max. 8 kbyte
● User data per job (of which consistent), max. 240 byte
Standard communication (FMS)
● supported Yes
Web server
● supported No
Number of connections
● overall 64
● usable for PG communication
— reserved for PG communication 1
— Adjustable for PG communication, max. 0
● usable for OP communication
— reserved for OP communication 1
— adjustable for OP communication, max. 0
● usable for S7 basic communication
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, max. 0
● usable for S7 communication
— reserved for S7 communication 0
— Adjustable for S7 communication, max. 0
● usable for routing
— Reserved for routing 0
— adjustable for routing, max. 0
S7 message functions
Number of login stations for message functions, max. 63
Symbol-related messages Yes
SCAN procedure Yes
Block related messages Yes
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 1 000
Alarm 8-blocks Yes
● Number of instances for alarm 8 and S7 communication blocks, max. 4 000
● preset, max. 600
Process control messages Yes
Number of archives that can log on simultaneously (SFB 37 AR_SEND) 32
Number of messages
● overall, max. 1 024
● in 100 ms grid, max. 128
● in 500 ms grid, max. 512
● in 1000 ms grid, max. 1 024
Number of additional values
● with 100 ms grid, max. 1
● with 500, 1000 ms grid, max. 10
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable Yes
● Number of variables, max. 70
Forcing
● Forcing Yes
● Number of variables, max. 512
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— can be set Yes
— preset 120
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Configuration
Configuration software
● STEP 7 Yes
programming
● Nesting levels 7
● Access to consistent data in process image Yes
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Number of simultaneously active SFCs
— DPSYC_FR 2
— D_ACT_DP 8
— RD_REC 8
— WR_REC 8
— WR_PARM 8
— PARM_MOD 1
— WR_DPARM 2
— DPNRM_DG 8
— RDSYSST 8
— DP_TOPOL 1
Number of simultaneously active SFBs
— RD_REC 8
— WR_REC 8
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 50 mm
Height 290 mm
Depth 219 mm
Weights
Weight, approx. 0.9 kg